Model NO.: Medium Voltage XLPE Insulated Steel Wire Armoured
Certification: ISO, CCC, SABS
Brand: Jiapu
Trademark: JP
Transport Package: Export Wooden Drum or Wooden Steel Drum
Origin: China
HS Code: 8544492100
Model NO.: Medium Voltage XLPE Insulated Steel Wire Armoured
Certification: ISO, CCC, SABS
Brand: Jiapu
Trademark: JP
Transport Package: Export Wooden Drum or Wooden Steel Drum
Origin: China
HS Code: 8544492100
Medium Voltage XLPE Insulated Steel Wire Armoured Power Cable

Application:
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.

Property:

1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.

Specifications:
IEC60502,designing and manufacturing special power cable according to the other standards required by the customers.

1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

 No.X Nominal Cross Section of Conductor

Nominal Diameter of Conductor

Nominal Thickness of Insulation

Nominal Thickness of Copper Tape Screen

Nominal Thickness of Inner Sheath

Nominal Thickness of Steel Tape Armouring

Nominal Thickness of PVC Sheath

Approx. Overall Diameter

Approx. Weight

Al Conductor

Cu Conductor

No. X mm2

mm

mm

mm

mm

mm

mm

mm

kg/m

kg/m

3 X 25

6.0

2.5

0.1

1.2

0.2

1.9

37.9

1.87

2.32

3 X 35

6.9

2.5

0.1

1.3

0.5

2.0

41.5

2.10

2.73

3 X50

8.2

2.5

0.1

1.3

0.5

2.0

44.3

2.37

3.22

3 X 70

9.7

2.5

0.1

1.4

0.5

2.1

47.9

2.77

4.00

3 X 95

11.3

2.5

0.1

1.4

0.5

2.2

51.6

3.21

4.91

3 X 120

12.8

2.5

0.1

1.5

0.5

2.4

55.4

3.69

5.84

3 X 150

14.2

2.5

0.1

1.5

0.5

2.5

58.6

4.15

6.85

3 X 185

15.9

2.5

0.1

1.5

0.5

2.6

62.5

4.73

8.11

3 X 240

18.3

2.6

0.1

1.6

0.5

2.7

68.5

5.62

10.05

3 X 300

20.4

2.8

0.1

1.7

0.5

2.9

74.5

6.55

12.11

3 X 400

23.2

3.0

0.1

1.9

0.8

3.2

83.6

8.78

15.86

3 X 500

26.4

3.2

0.1

2.1

0.8

3.4

93.0

10.52

18.85


2)6/10(12)kV,6.35/11(12)kV,,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor

Nominal Diameter of Conductor

Nominal Thickness of Insulation

Nominal Thickness of Copper Tape Screen

Nominal Thickness of Inner Sheath

Nominal Thickness of Steel Tape Armouring

Nominal Thickness of PVC Sheath

Approx. Overall Diameter

Approx. Weight

Al Conductor

Cu Conductor

No. X mm2

mm

mm

mm

mm

mm

mm

mm

kg/m

kg/m

3 X 25

6.0

3.4

0.1

1.3

0.5

2.0

43.4

2.16

2.61

3 X 35

6.9

3.4

0.1

1.3

0.5

2.0

45.4

2.36

2.99

3 X50

8.2

3.4

0.1

1.4

0.5

2.2

48.8

2.69

3.54

3 X 70

9.7

3.4

0.1

1.5

0.5

2.3

52.4

3.10

4.33

3 X 95

11.3

3.4

0.1

1.5

0.5

2.4

56.1

3.56

5.26

3 X 120

12.8

3.4

0.1

1.5

0.5

2.5

59.5

4.04

6.19

3 X 150

14.2

3.4

0.1

1.5

0.5

2.6

62.7

4.49

7.19

3 X 185

15.9

3.4

0.1

1.6

0.5

2.6

66.6

5.12

8.49

3 X 240

18.3

3.4

0.1

1.7

0.5

2.8

72.4

5.99

10.42

3 X 300

20.4

3.4

0.1

1.8

0.5

3.0

77.5

6.86

12.42

3 X 400

23.2

3.4

0.1

1.9

0.8

3.2

85.4

8.97

16.05

3 X 500

26.4

3.4

0.1

2.0

0.8

3.4

93.7

10.65

19.50


3)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor

Nominal Diameter of Conductor

Nominal Thickness of Insulation

Nominal Thickness of Copper Tape Screen

Nominal Thickness of Inner Sheath

Nominal Thickness of Steel Tape Armouring

Nominal Thickness of PVC Sheath

Approx. Overall Diameter

Approx. Weight

Al Conductor

Cu Conductor

No. X mm2

mm

mm

mm

mm

mm

mm

mm

kg/m

kg/m

3 X 25

6.0

4.5

0.1

1.4

0.5

2.1

48.6

2.53

2.98

3 X 35

6.9

4.5

0.1

1.4

0.5

2.2

50.7

2.76

3.39

3 X50

8.2

4.5

0.1

1.5

0.5

2.3

53.9

3.10

3.95

3 X 70

9.7

4.5

0.1

1.5

0.5

2.4

57.4

3.51

4.74

3 X 95

11.3

4.5

0.1

1.5

0.5

2.6

61.2

4.05

5.75

3 X 120

12.8

4.5

0.1

1.6

0.5

2.6

64.7

4.56

6.72

3 X 150

14.2

4.5

0.1

1.6

0.5

2.7

67.9

5.04

7.74

3 X 185

15.9

4.5

0.1

1.7

0.5

2.8

71.9

5.66

9.04

3 X 240

18.3

4.5

0.1

1.8

0.5

3.0

77.7

6.56

11.00

3 X 300

20.4

4.5

0.1

1.9

0.8

3.2

84.1

8.39

13.96

3 X 400

23.2

4.5

0.1

2.0

0.8

3.3

90.5

9.71

16.79

3 X 500

26.4

4.5

0.1

2.1

0.8

3.5

98.8

11.45

20.57


4)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor

Nominal Diameter of Conductor

Nominal Thickness of Insulation

Nominal Thickness of Copper Tape Screen

Nominal Thickness of Inner Sheath

Nominal Thickness of Steel Tape Armouring

Nominal Thickness of PVC Sheath

Approx. Overall Diameter

Approx. Weight

Al Conductor

Cu Conductor

No. X mm2

mm

mm

mm

mm

mm

mm

mm

kg/m

kg/m

3 X 25

 

 

 

 

 

 

 

 

 

3 X 35

6.9

5.5

0.1

1.5

0.5

2.4

55.6

3.14

3.77

3 X50

8.2

5.5

0.1

1.5

0.5

2.5

58.6

3.49

4.34

3 X 70

9.7

5.5

0.1

1.5

0.5

2.6

62.1

3.93

5.16

3 X 95

11.3

5.5

0.1

1.6

0.5

2.6

65.7

4.46

6.16

3 X 120

12.8

5.5

0.1

1.7

0.5

2.7

69.4

5.00

7.15

3 X 150

14.2

5.5

0.1

1.7

0.5

2.8

72.6

5.49

8.19

3 X 185

15.9

5.5

0.1

1.8

0.5

3.0

76.9

6.16

9.53

3 X 240

18.3

5.5

0.1

1.9

0.8

3.2

83.9

7.87

12.31

3 X 300

20.4

5.5

0.1

2.0

0.8

3.2

88.6

8.96

14.52

3 X 400

23.2

5.5

0.1

2.1

0.8

3.5

95.4

10.35

17.43

3 X 500

26.4

5.5

0.1

2.2

0.8

3.7

103.7

12.45

20.23


5)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor

Nominal Diameter of Conductor

Nominal Thickness of Insulation

Nominal Thickness of Copper Tape Screen

Nominal Thickness of Inner Sheath

Nominal Thickness of Steel Tape Armouring

Nominal Thickness of PVC Sheath

Approx. Overall Diameter

Approx. Weight

Al Conductor

Cu Conductor

No. X mm2

mm

mm

mm

mm

mm

mm

mm

kg/m

kg/m

3 X 25

 

 

 

 

 

 

 

 

 

3 X 35

 

 

 

 

 

 

 

 

 

3 X50

8.2

8.0

0.1

1.7

0.5

2.8

70.4

4.56

5.41

3 X 70

9.7

8.0

0.1

1.7

0.5

2.9

73.9

5.04

6.26

3 X 95

11.3

8.0

0.1

1.8

0.5

3.0

77.7

5.62

7.32

3 X 120

12.8

8.0

0.1

1.9

0.8

3.2

82.8

6.99

9.15

3 X 150

14.2

8.0

0.1

1.9

0.8

3.2

85.8

7.56

10.26

3 X 185

15.9

8.0

0.1

2.0

0.8

3.3

89.9

8.30

11.67

3 X 240

18.3

8.0

0.1

2.1

0.8

3.5

95.7

9.36

13.79

3 X 300

20.4

8.0

0.1

2.2

0.8

3.6

100.6

10.51

16.07

3 X 400

23.2

8.0

0.1

2.3

0.8

3.8

107.2

11.99

19.07

3 X 500

26.4

8.0

0.1

2.4

0.8

4.0

120.1

14.15

23.85

  Medium Voltage XLPE Insulated Steel Wire Armoured Power Cable

Application:
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.

Property:

1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.

Specifications:
IEC60502,designing and manufacturing special power cable according to the other standards required by the customers.

1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

 No.X Nominal Cross Section of Conductor

Nominal Diameter of Conductor

Nominal Thickness of Insulation

Nominal Thickness of Copper Tape Screen

Nominal Thickness of Inner Sheath

Nominal Thickness of Steel Tape Armouring

Nominal Thickness of PVC Sheath

Approx. Overall Diameter

Approx. Weight

Al Conductor

Cu Conductor

No. X mm2

mm

mm

mm

mm

mm

mm

mm

kg/m

kg/m

3 X 25

6.0

2.5

0.1

1.2

0.2

1.9

37.9

1.87

2.32

3 X 35

6.9

2.5

0.1

1.3

0.5

2.0

41.5

2.10

2.73

3 X50

8.2

2.5

0.1

1.3

0.5

2.0

44.3

2.37

3.22

3 X 70

9.7

2.5

0.1

1.4

0.5

2.1

47.9

2.77

4.00

3 X 95

11.3

2.5

0.1

1.4

0.5

2.2

51.6

3.21

4.91

3 X 120

12.8

2.5

0.1

1.5

0.5

2.4

55.4

3.69

5.84

3 X 150

14.2

2.5

0.1

1.5

0.5

2.5

58.6

4.15

6.85

3 X 185

15.9

2.5

0.1

1.5

0.5

2.6

62.5

4.73

8.11

3 X 240

18.3

2.6

0.1

1.6

0.5

2.7

68.5

5.62

10.05

3 X 300

20.4

2.8

0.1

1.7

0.5

2.9

74.5

6.55

12.11

3 X 400

23.2

3.0

0.1

1.9

0.8

3.2

83.6

8.78

15.86

3 X 500

26.4

3.2

0.1

2.1

0.8

3.4

93.0

10.52

18.85


2)6/10(12)kV,6.35/11(12)kV,,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor

Nominal Diameter of Conductor

Nominal Thickness of Insulation

Nominal Thickness of Copper Tape Screen

Nominal Thickness of Inner Sheath

Nominal Thickness of Steel Tape Armouring

Nominal Thickness of PVC Sheath

Approx. Overall Diameter

Approx. Weight

Al Conductor

Cu Conductor

No. X mm2

mm

mm

mm

mm

mm

mm

mm

kg/m

kg/m

3 X 25

6.0

3.4

0.1

1.3

0.5

2.0

43.4

2.16

2.61

3 X 35

6.9

3.4

0.1

1.3

0.5

2.0

45.4

2.36

2.99

3 X50

8.2

3.4

0.1

1.4

0.5

2.2

48.8

2.69

3.54

3 X 70

9.7

3.4

0.1

1.5

0.5

2.3

52.4

3.10

4.33

3 X 95

11.3

3.4

0.1

1.5

0.5

2.4

56.1

3.56

5.26

3 X 120

12.8

3.4

0.1

1.5

0.5

2.5

59.5

4.04

6.19

3 X 150

14.2

3.4

0.1

1.5

0.5

2.6

62.7

4.49

7.19

3 X 185

15.9

3.4

0.1

1.6

0.5

2.6

66.6

5.12

8.49

3 X 240

18.3

3.4

0.1

1.7

0.5

2.8

72.4

5.99

10.42

3 X 300

20.4

3.4

0.1

1.8

0.5

3.0

77.5

6.86

12.42

3 X 400

23.2

3.4

0.1

1.9

0.8

3.2

85.4

8.97

16.05

3 X 500

26.4

3.4

0.1

2.0

0.8

3.4

93.7

10.65

19.50


3)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor

Nominal Diameter of Conductor

Nominal Thickness of Insulation

Nominal Thickness of Copper Tape Screen

Nominal Thickness of Inner Sheath

Nominal Thickness of Steel Tape Armouring

Nominal Thickness of PVC Sheath

Approx. Overall Diameter

Approx. Weight

Al Conductor

Cu Conductor

No. X mm2

mm

mm

mm

mm

mm

mm

mm

kg/m

kg/m

3 X 25

6.0

4.5

0.1

1.4

0.5

2.1

48.6

2.53

2.98

3 X 35

6.9

4.5

0.1

1.4

0.5

2.2

50.7

2.76

3.39

3 X50

8.2

4.5

0.1

1.5

0.5

2.3

53.9

3.10

3.95

3 X 70

9.7

4.5

0.1

1.5

0.5

2.4

57.4

3.51

4.74

3 X 95

11.3

4.5

0.1

1.5

0.5

2.6

61.2

4.05

5.75

3 X 120

12.8

4.5

0.1

1.6

0.5

2.6

64.7

4.56

6.72

3 X 150

14.2

4.5

0.1

1.6

0.5

2.7

67.9

5.04

7.74

3 X 185

15.9

4.5

0.1

1.7

0.5

2.8

71.9

5.66

9.04

3 X 240

18.3

4.5

0.1

1.8

0.5

3.0

77.7

6.56

11.00

3 X 300

20.4

4.5

0.1

1.9

0.8

3.2

84.1

8.39

13.96

3 X 400

23.2

4.5

0.1

2.0

0.8

3.3

90.5

9.71

16.79

3 X 500

26.4

4.5

0.1

2.1

0.8

3.5

98.8

11.45

20.57


4)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor

Nominal Diameter of Conductor

Nominal Thickness of Insulation

Nominal Thickness of Copper Tape Screen

Nominal Thickness of Inner Sheath

Nominal Thickness of Steel Tape Armouring

Nominal Thickness of PVC Sheath

Approx. Overall Diameter

Approx. Weight

Al Conductor

Cu Conductor

No. X mm2

mm

mm

mm

mm

mm

mm

mm

kg/m

kg/m

3 X 25

 

 

 

 

 

 

 

 

 

3 X 35

6.9

5.5

0.1

1.5

0.5

2.4

55.6

3.14

3.77

3 X50

8.2

5.5

0.1

1.5

0.5

2.5

58.6

3.49

4.34

3 X 70

9.7

5.5

0.1

1.5

0.5

2.6

62.1

3.93

5.16

3 X 95

11.3

5.5

0.1

1.6

0.5

2.6

65.7

4.46

6.16

3 X 120

12.8

5.5

0.1

1.7

0.5

2.7

69.4

5.00

7.15

3 X 150

14.2

5.5

0.1

1.7

0.5

2.8

72.6

5.49

8.19

3 X 185

15.9

5.5

0.1

1.8

0.5

3.0

76.9

6.16

9.53

3 X 240

18.3

5.5

0.1

1.9

0.8

3.2

83.9

7.87

12.31

3 X 300

20.4

5.5

0.1

2.0

0.8

3.2

88.6

8.96

14.52

3 X 400

23.2

5.5

0.1

2.1

0.8

3.5

95.4

10.35

17.43

3 X 500

26.4

5.5

0.1

2.2

0.8

3.7

103.7

12.45

20.23


5)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/STA/PVC Armoured Power Cable

No.X Nominal Cross Section of Conductor

Nominal Diameter of Conductor

Nominal Thickness of Insulation

Nominal Thickness of Copper Tape Screen

Nominal Thickness of Inner Sheath

Nominal Thickness of Steel Tape Armouring

Nominal Thickness of PVC Sheath

Approx. Overall Diameter

Approx. Weight

Al Conductor

Cu Conductor

No. X mm2

mm

mm

mm

mm

mm

mm

mm

kg/m

kg/m

3 X 25

 

 

 

 

 

 

 

 

 

3 X 35

 

 

 

 

 

 

 

 

 

3 X50

8.2

8.0

0.1

1.7

0.5

2.8

70.4

4.56

5.41

3 X 70

9.7

8.0

0.1

1.7

0.5

2.9

73.9

5.04

6.26

3 X 95

11.3

8.0

0.1

1.8

0.5

3.0

77.7

5.62

7.32

3 X 120

12.8

8.0

0.1

1.9

0.8

3.2

82.8

6.99

9.15

3 X 150

14.2

8.0

0.1

1.9

0.8

3.2

85.8

7.56

10.26

3 X 185

15.9

8.0

0.1

2.0

0.8

3.3

89.9

8.30

11.67

3 X 240

18.3

8.0

0.1

2.1

0.8

3.5

95.7

9.36

13.79

3 X 300

20.4

8.0

0.1

2.2

0.8

3.6

100.6

10.51

16.07

3 X 400

23.2

8.0

0.1

2.3

0.8

3.8

107.2

11.99

19.07

3 X 500

26.4

8.0

0.1

2.4

0.8

4.0

120.1

14.15

23.85

 

Mirror Heating Elements can be used in many field. Such as car rearview mirror.bathroom mirror.camera even in flower showcase freezer.With the property of automatically power change,the PET heating film can convert the electrical energy into thermal energy efficiently which makes the mirror suface's temperature rise to prevent steam from condensing. Not only did we supply the good quality of  manufactured goods but also offer service of custom-made mirror heating film.We look forward to build business cooperation with customers worldwide.

Mirror Heating Elements

Rearview Mirror Heating Film,Ptc Heating Film , Mirror Heating Elements,Bathroom Mirror Heating Film

ShenZhen XingHongChang Electric CO., LTD. , http://www.xhc-heater.com